Skip to content

Hemoglobin A1c (HbA1c): normal range and interpretation

HbA1c shows the percentage of hemoglobin that has become bound to glucose, and reflects the average blood glucose of the last two or three months, which is the life span of the red cell.

Reviewed by the MIROTECA medical team · November 2026
Advertisement
Advertisement
Approximate reference values: Below 5.7% (below 39 mmol/mol). Each laboratory publishes its own range according to the method it uses.
Units

Percent (NGSP) and mmol/mol (IFCC)

HbA1c is reported in the United States as a percentage (NGSP); many other countries use mmol/mol (IFCC). The pairs shown here (5.7% = 39, 6.4% = 46, 6.5% = 48 and 7% = 53 mmol/mol) follow the published master equation IFCC = (NGSP − 2.152) / 0.09148, rounded to whole numbers.

What it is and why it is measured

HbA1c shows the percentage of hemoglobin that has become bound to glucose, and reflects the average blood glucose of the last two or three months, which is the life span of the red cell. It needs no fasting and is more stable than a single glucose, so it is used both to diagnose diabetes and to follow its control.

Next: Glucose · Hemoglobin

High hemoglobin A1c: causes

Diabetes mellitus

A value of 6.5% (48 mmol/mol) or higher meets the diagnostic criterion. Between 5.7 and 6.4% (39–46 mmol/mol) lies prediabetes.

Insufficient control in known diabetes

The usual target is around 7% (53 mmol/mol), although it is individualized: higher values are accepted in older people or those at risk of hypoglycemia, and stricter ones in young people with a recent diagnosis.

False elevations

Iron deficiency, B12 deficiency and kidney failure lengthen the life of the red cell or alter the measurement, and raise HbA1c without the average glucose justifying it.

Low hemoglobin A1c: causes

Situations with accelerated red cell turnover

Hemolytic anemias, recent bleeding, transfusions and pregnancy shorten the life of the red cell and give falsely low values, which underestimate the real control.

Hemoglobinopathies

Some hemoglobin variants interfere with certain measurement methods and make it necessary to use other techniques or to rely on fructosamine.

How it is read alongside other tests

It is checked against the recorded glucose values: a marked discordance between a good HbA1c and high glucose values, or the opposite, suggests one of the interferences above and not a real change in control.

Common interpretation errors

Frequently asked questions

What period does HbA1c reflect?

The previous two or three months, which is approximately the half-life of the red cell. Changes in the last weeks weigh more than those at the beginning of the period, but it does not reflect what happened in the last few days.

Why may HbA1c not match the glucose values?

Because any situation that alters the life of the red cell changes the result. Hemolytic anemia, recent bleeding and pregnancy lower it falsely, whereas iron deficiency, B12 deficiency and kidney failure tend to raise it.

Related tests

Important notice

This page is educational material for medical training: it describes the clinical meaning of the test and the causes of its abnormalities. It is not a diagnosis or a treatment recommendation, and it does not replace the laboratory report or the individual clinical assessment, which interprets each result in its context.

Advertisement
▶ Play today's clinical case See all medical diagrams