Scaphoid fracture: snuffbox, Herbert, MRI and cast or screw
On this page
MIROTECA medical team · Reviewed 23 Nov 2026 · 5 min read
The most frequently fractured carpal bone (up to 70% of carpal fractures), mainly in men aged 20-29 after a fall on the hyperextended wrist. Its retrograde blood supply explains necrosis and nonunion of the proximal pole, and many are not visible on the first X-ray1.
Snuffbox tenderness: the most sensitive test (87-100%). Combined with tubercle tenderness and thumb axial compression within 24 h, sensitivity 100% and specificity 74%1.
Wrist X-rays and scaphoid views; if normal with suspicion, MRI (or CT) within the first week rather than immobilising and repeating at 7-10 days1.
MRI is the test of choice for occult fractures (sensitivity and specificity near 100%); CT is for surgical planning1.
The dorsal scaphoid artery supplies the proximal 70-80% retrogradely: the proximal pole is the most prone to necrosis1.
Displaced, unstable and proximal pole fractures are operated on1.
Anatomy and mechanism
An S-shaped bone with its axis at about 45°; tubercle, waist and poles. Fractures: waist 70%, distal pole 20%, tubercle 5% and proximal pole 5%. 70-80% of its surface is cartilage1. It breaks with the wrist hyperextended and radially deviated; if displaced, the proximal pole extends with the lunate and the distal one flexes: the «humpback» deformity1.
Nonoperative for stable undisplaced fractures: below-elbow cast with the wrist in a functional position, thumb free; tubercle fractures heal in almost 100%. Check union with CT in waist and distal pole fractures13.
Surgery (headless compression screw along the axis): displaced, unstable and proximal pole fractures1.
Approaches
Percutaneous volar: undisplaced or reducible waist and distal pole fractures. Percutaneous dorsal: proximal pole.
Arthroscopy: confirms reduction, screw position and associated injuries.
Open: angulated, irreducible or comminuted; volar preserves the dorsal blood supply, dorsal damages it but gives better access to the axis1.
5-10% with nonoperative care, more in the proximal pole; rare after good fixation1.
Of surgery
0-29%: malpositioned screw, osteonecrosis, malunion and implant removal1.
Of casting
Stiffness, atrophy, complex regional pain syndrome and transient neuropathies1.
Key studies
Each card summarises the abstract of the study, with its link.
SWIFFTMulticentre randomised trial (31 UK hospitals)
Patients
439 adults with a bicortical waist fracture displaced 2 mm or less
Result
No difference in PRWE at one year between early screw fixation (11.9) and cast with fixation only for nonunion (14.0). Potentially serious complications: 14% with surgery and 1% with cast; cast problems: 2% and 18%.
What it means
For waist fractures ≤ 2 mm, cast first and operate only on nonunions.